Contract award: delivery of transformers, reactors and resistors
extinguishing overhead.
The contract is for the supply of the following devices:
- 2 000 kVA transformer 30/15 kV connection group DY5, culvert GN -
enamel, feedthrough connectors DN- execution, the execution of the
transformer conservator, an additional transformer to protect against
voltage surges from the 30 kV surge arresters should be adopted: Uc- 36
kV Rated discharge current - 10 kA short-circuit resistance: 20 kA /
0.2s,
- Grounding transformer oil phase TUOe type 275/15 with a ratio of
15.75 kV / 042 kV with power needs its own 100 kVA, the group calls
ZNyn11, equipped with protective insulation against birds for culverts
DN, SN,
- Extinguishing oil gland type DGOe275 / 15, rated voltage of 15.75
kV 273 kVA power compensation, compensation coupling 5-30, CT 40 / 5A,
10P5, 30VA,
- Resistor type BWR overhead AWSCz 20A; rated https://www.bloglovin.com/@electronics/tools-you-need-for-repairing-electronic-parts voltage of 15kV
networks; forcing the rated current of 20A; control voltage 220 V DC;
spacing of 550 mm wheels.
Total final value of contract(s): 335 600 PLN Excluding VAT
Date of contract award: V.1.2)Information about offers
Number of offers received: 1
Contractor name : TRAFTA SP. Z O.O.
Contractor address : Ul. 1 Maja 152
42-300 MyszkEw
POLAND
Implementing agency : PKP Energetyka S.A. Oddzial w Warszawie
Uslugi Zaklad Swietokrzyski
Paderewskiego 43/45
For the attention of: Krzysztof Wolski
25-502 Kielce
POLAND
Telephone: +48 697040428
Fax: +48 413456153
E-mail: k.wolski@pkpenergetyka.pl
Internet address(es):
General address of the contracting entity:
http://www.pkpenergetyka.pl
Country :Poland
[c] 2015 Al Bawaba (Albawaba.com) Provided by SyndiGate Media Inc.
( Syndigate.info ).
COPYRIGHT 2015 SyndiGate Media Inc.
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2015 Gale, Cengage Learning. All rights reserved.
https://www.thefreelibrary.com/Transformers.-a0431591491
extinguishing overhead.
The contract is for the supply of the following devices:
- 2 000 kVA transformer 30/15 kV connection group DY5, culvert GN -
enamel, feedthrough connectors DN- execution, the execution of the
transformer conservator, an additional transformer to protect against
voltage surges from the 30 kV surge arresters should be adopted: Uc- 36
kV Rated discharge current - 10 kA short-circuit resistance: 20 kA /
0.2s,
- Grounding transformer oil phase TUOe type 275/15 with a ratio of
15.75 kV / 042 kV with power needs its own 100 kVA, the group calls
ZNyn11, equipped with protective insulation against birds for culverts
DN, SN,
- Extinguishing oil gland type DGOe275 / 15, rated voltage of 15.75
kV 273 kVA power compensation, compensation coupling 5-30, CT 40 / 5A,
10P5, 30VA,
- Resistor type BWR overhead AWSCz 20A; rated https://www.bloglovin.com/@electronics/tools-you-need-for-repairing-electronic-parts voltage of 15kV
networks; forcing the rated current of 20A; control voltage 220 V DC;
spacing of 550 mm wheels.
Total final value of contract(s): 335 600 PLN Excluding VAT
Date of contract award: V.1.2)Information about offers
Number of offers received: 1
Contractor name : TRAFTA SP. Z O.O.
Contractor address : Ul. 1 Maja 152
42-300 MyszkEw
POLAND
Implementing agency : PKP Energetyka S.A. Oddzial w Warszawie
Uslugi Zaklad Swietokrzyski
Paderewskiego 43/45
For the attention of: Krzysztof Wolski
25-502 Kielce
POLAND
Telephone: +48 697040428
Fax: +48 413456153
E-mail: k.wolski@pkpenergetyka.pl
Internet address(es):
General address of the contracting entity:
http://www.pkpenergetyka.pl
Country :Poland
[c] 2015 Al Bawaba (Albawaba.com) Provided by SyndiGate Media Inc.
( Syndigate.info ).
COPYRIGHT 2015 SyndiGate Media Inc.
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2015 Gale, Cengage Learning. All rights reserved.
https://www.thefreelibrary.com/Transformers.-a0431591491